EnEV2009
Basics:
Energetic standard of installed windows compared to German EnEV 2009:
Record ID: 12
End of time frame: 2014
Percentage of window surface area (pWindows) regarding net zone surface area (AZone):
Residential buildings:
Single-family-house (number of apartments = 1)
Directly adjacent neighboring buildings (flanking = 0): none
0.195
Directly adjacent neighboring buildings (flanking = 1): one side
0.199
Directly adjacent neighboring buildings (flanking = 2): two sides
0.201
Multi-family-houses (number of apartments > 1)
Directly adjacent neighboring buildings (flanking = 0): none
0.145
Directly adjacent neighboring buildings (flanking = 1): one side
0.182
Directly adjacent neighboring buildings (flanking = 2): two sides
0.186
Non-residential buildings:
generally: 0.3
Roof:
U-Value of roof without add-on insulation (roofUU):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.2 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.2 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.2 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.2 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.2 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.2 W/(m2*K)
Thickness of roof without add-on insulation (roofThicknessU):
Construction Type: concrete or brick (massive, type = 1)
0.18 m
Construction Type: wooden (wood, type = 2)
0.18 m
Construction Type: mixed (both, type = 3)
0.18 m
Average density of roof material without add-on insulation (roofRhoU):
Construction Type: concrete or brick (massive, type = 1)
418 kg/m3
Construction Type: wooden (wood, type = 2)
418 kg/m3
Construction Type: mixed (both, type = 3)
418 kg/m3
Average specific heat capacity of roof material without add-on insulation (roofCpU):
Construction Type: concrete or brick (massive, type = 1)
1773 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1773 J/(kg*K)
Construction Type: mixed (both, type = 3)
1773 kg/m3
Outer Walls:
U-Value of outer walls without add-on insulation (wallUU):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.28 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.28 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.28 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.28 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.28 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.28 W/(m2*K)
Thickness of outer walls without add-on insulation (wallThicknessU):
Construction Type: concrete or brick (massive, type = 1)
0.24 m
Construction Type: wooden (wood, type = 2)
0.16 m
Construction Type: mixed (both, type = 3)
0.20 m
Average density of outer walls material without add-on insulation (wallRhoU):
Construction Type: concrete or brick (massive, type = 1)
1180 kg/m3
Construction Type: wooden (wood, type = 2)
433 kg/m3
Construction Type: mixed (both, type = 3)
806.5 kg/m3
Average specific heat capacity of outer walls material without add-on insulation (wallCpU):
Construction Type: concrete or brick (massive, type = 1)
850 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1814 J/(kg*K)
Construction Type: mixed (both, type = 3)
1332 J/(kg*K)
Top-level ceiling:
U-Value top-level ceiling with adequate insulation (ceilingUUg):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.2 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.2 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.2 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.2 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.2 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.2 W/(m2*K)
U-Value top-level ceiling without adequate insulation (ceilingUUu):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
3.7 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.2 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.2 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.2 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.2 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.2 W/(m2*K)
Thickness of top-level ceiling with adequate insulation (ceilingThicknessUg):
Construction Type: concrete or brick (massive, type = 1)
0.3 m
Construction Type: wooden (wood, type = 2)
0.22 m
Construction Type: mixed (both, type = 3)
0.26 m
Thickness of top-level ceiling without adequate insulation (ceilingThicknessUu):
Construction Type: concrete or brick (massive, type = 1)
0.2 m
Construction Type: wooden (wood, type = 2)
0.06 m
Construction Type: mixed (both, type = 3)
0.13 m
Average density of top-level ceiling with adequate insulation (ceilingRhoUg):
Construction Type: concrete or brick (massive, type = 1)
2353 kg/m3
Construction Type: wooden (wood, type = 2)
492 kg/m3
Construction Type: mixed (both, type = 3)
1402.5 kg/m3
Average density of top-level ceiling without adequate insulation (ceilingRhoUu):
Construction Type: concrete or brick (massive, type = 1)
2400 kg/m3
Construction Type: wooden (wood, type = 2)
538 kg/m3
Construction Type: mixed (both, type = 3)
1422.5 kg/m3
Average specific heat capacity of top-level ceiling with adequate insulation (CeilingCpUg):
Construction Type: concrete or brick (massive, type = 1)
880 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1700 J/(kg*K)
Construction Type: mixed (both, type = 3)
1290 J/(kg*K)
Average specific heat capacity of top-level ceiling without adequate insulation (CeilingCpUu):
Construction Type: concrete or brick (massive, type = 1)
880 J/(kg*K)
Construction Type: wooden (wood, type = 2)
2100 J/(kg*K)
Construction Type: mixed (both, type = 3)
1490 J/(kg*K)
Floor:
U-Value of floor without add-on insulation (floorUU):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.35 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.35 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.35 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
0.35 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.35 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.35 W/(m2*K)
Thickness of floor without add-on insulation (floorThicknessU):
Construction Type: concrete or brick (massive, type = 1)
0.25 m
Construction Type: wooden (wood, type = 2)
0.25 m
Construction Type: mixed (both, type = 3)
0.25 m
Average density of floor material without add-on insulation (floorRhoU):
Construction Type: concrete or brick (massive, type = 1)
2396 kg/m3
Construction Type: wooden (wood, type = 2)
2396 kg/m3
Construction Type: mixed (both, type = 3)
2396 kg/m3
Average specific heat capacity of floor material without add-on insulation (floorCpU):
Construction Type: concrete or brick (massive, type = 1)
879 J/(kg*K)
Construction Type: wooden (wood, type = 2)
879 J/(kg*K)
Construction Type: mixed (both, type = 3)
879 J/(kg*K)