To1948
Basics:
Energetic standard of installed windows compared to German situation between 1919 and 1948:
Record ID: 2
End of time frame: 1948
Percentage of window surface area (pWindows) regarding net zone surface area (AZone):
Residential buildings:
Single-family-house (number of apartments = 1)
Directly adjacent neighboring buildings (flanking = 0): none
0.200
Directly adjacent neighboring buildings (flanking = 1): one side
0.179
Directly adjacent neighboring buildings (flanking = 2): two sides
0.153
Multi-family-houses (number of apartments > 1)
Directly adjacent neighboring buildings (flanking = 0): none
0.184
Directly adjacent neighboring buildings (flanking = 1): one side
0.155
Directly adjacent neighboring buildings (flanking = 2): two sides
0.178
Non-residential buildings:
generally: 0.3
Roof:
U-Value of roof without add-on insulation (roofUU):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
1.3 W/(m2*K)
Construction Type: wooden (wood, type = 2)
2.6 W/(m2*K)
Construction Type: mixed (both, type = 3)
1.75 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
2.1 W/(m2*K)
Construction Type: wooden (wood, type = 2)
1.4 W/(m2*K)
Construction Type: mixed (both, type = 3)
1.75 W/(m2*K)
Thickness of roof without add-on insulation (roofThicknessU):
Construction Type: concrete or brick (massive, type = 1)
0.26 m
Construction Type: wooden (wood, type = 2)
0.26 m
Construction Type: mixed (both, type = 3)
0.26 m
Average density of roof material without add-on insulation (roofRhoU):
Construction Type: concrete or brick (massive, type = 1)
1122 kg/m3
Construction Type: wooden (wood, type = 2)
350 kg/m3
Construction Type: mixed (both, type = 3)
736 kg/m3
Average specific heat capacity of roof material without add-on insulation (roofCpU):
Construction Type: concrete or brick (massive, type = 1)
1129 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1665 J/(kg*K)
Construction Type: mixed (both, type = 3)
1397 kg/m3
Outer Walls:
U-Value of outer walls without add-on insulation (wallUU):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
1.7 W/(m2*K)
Construction Type: wooden (wood, type = 2)
2.0 W/(m2*K)
Construction Type: mixed (both, type = 3)
1.85 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
1.7 W/(m2*K)
Construction Type: wooden (wood, type = 2)
2.0 W/(m2*K)
Construction Type: mixed (both, type = 3)
1.85 W/(m2*K)
Thickness of outer walls without add-on insulation (wallThicknessU):
Construction Type: concrete or brick (massive, type = 1)
0.32 m
Construction Type: wooden (wood, type = 2)
0.24 m
Construction Type: mixed (both, type = 3)
0.28 m
Average density of outer walls material without add-on insulation (wallRhoU):
Construction Type: concrete or brick (massive, type = 1)
1650 kg/m3
Construction Type: wooden (wood, type = 2)
1146 kg/m3
Construction Type: mixed (both, type = 3)
1398 kg/m3
Average specific heat capacity of outer walls material without add-on insulation (wallCpU):
Construction Type: concrete or brick (massive, type = 1)
850 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1085 J/(kg*K)
Construction Type: mixed (both, type = 3)
967.5 J/(kg*K)
Top-level ceiling:
U-Value top-level ceiling with adequate insulation (ceilingUUg):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
2.1 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.8 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.95 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
2.1 W/(m2*K)
Construction Type: wooden (wood, type = 2)
1.4 W/(m2*K)
Construction Type: mixed (both, type = 3)
1.75 W/(m2*K)
U-Value top-level ceiling without adequate insulation (ceilingUUu):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
3.7 W/(m2*K)
Construction Type: wooden (wood, type = 2)
1.21 W/(m2*K)
Construction Type: mixed (both, type = 3)
2.455 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
2.1 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.8 W/(m2*K)
Construction Type: mixed (both, type = 3)
0.955 W/(m2*K)
Thickness of top-level ceiling with adequate insulation (ceilingThicknessUg):
Construction Type: concrete or brick (massive, type = 1)
0.21 m
Construction Type: wooden (wood, type = 2)
0.26 m
Construction Type: mixed (both, type = 3)
0.235 m
Thickness of top-level ceiling without adequate insulation (ceilingThicknessUu):
Construction Type: concrete or brick (massive, type = 1)
0.2 m
Construction Type: wooden (wood, type = 2)
0.26 m
Construction Type: mixed (both, type = 3)
0.23 m
Average density of top-level ceiling with adequate insulation (ceilingRhoUg):
Construction Type: concrete or brick (massive, type = 1)
2395 kg/m3
Construction Type: wooden (wood, type = 2)
1122 kg/m3
Construction Type: mixed (both, type = 3)
1758.5 kg/m3
Average density of top-level ceiling without adequate insulation (ceilingRhoUu):
Construction Type: concrete or brick (massive, type = 1)
2400 kg/m3
Construction Type: wooden (wood, type = 2)
1122 kg/m3
Construction Type: mixed (both, type = 3)
1761 kg/m3
Average specific heat capacity of top-level ceiling with adequate insulation (CeilingCpUg):
Construction Type: concrete or brick (massive, type = 1)
880 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1129 J/(kg*K)
Construction Type: mixed (both, type = 3)
1004.5 J/(kg*K)
Average specific heat capacity of top-level ceiling without adequate insulation (CeilingCpUu):
Construction Type: concrete or brick (massive, type = 1)
880 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1129 J/(kg*K)
Construction Type: mixed (both, type = 3)
1004.5 J/(kg*K)
Floor:
U-Value of floor without add-on insulation (floorUU):
Residential buildings:
Construction Type: concrete or brick (massive, type = 1)
1.2 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.8 W/(m2*K)
Construction Type: mixed (both, type = 3)
1.0 W/(m2*K)
Non-residential buildings:
Construction Type: concrete or brick (massive, type = 1)
1.2 W/(m2*K)
Construction Type: wooden (wood, type = 2)
0.8 W/(m2*K)
Construction Type: mixed (both, type = 3)
1.1 W/(m2*K)
Thickness of floor without add-on insulation (floorThicknessU):
Construction Type: concrete or brick (massive, type = 1)
0.33 m
Construction Type: wooden (wood, type = 2)
0.31 m
Construction Type: mixed (both, type = 3)
0.32 m
Average density of floor material without add-on insulation (floorRhoU):
Construction Type: concrete or brick (massive, type = 1)
1639 kg/m3
Construction Type: wooden (wood, type = 2)
727 kg/m3
Construction Type: mixed (both, type = 3)
1563.5 kg/m3
Average specific heat capacity of floor material without add-on insulation (floorCpU):
Construction Type: concrete or brick (massive, type = 1)
852 J/(kg*K)
Construction Type: wooden (wood, type = 2)
1189 J/(kg*K)
Construction Type: mixed (both, type = 3)
1020.5 J/(kg*K)